Control TechniquesFault codes

MaxAx fault codes and LED diagnostics

The Control Techniques MaxAx servo drive reports faults through the LEDs on its front panel and through the monitoring outputs on the signal connector, rather than with numerical trip codes. Everything below is taken from the Diagnostics and Fault finding sections of the MaxAx User Guide. Overvoltage, undervoltage and over-temperature clear themselves when the cause goes away; a resolver break or a short between connector pins needs the power removed for at least 10 seconds.

MaxAx fault indications

What each front panel LED and each monitoring output means, and what the drive does about it. The I²t LEDs indicate current limiting rather than a trip, so the drive keeps running.

MaxAx fault indications and what they mean
IndicationFaultMeaning and reset
Front panel LEDs
GreenDrive normalLit while the drive is functioning correctly. When it is out, at least one fault is detected
RedResolver breakFault in the resolver circuit: resolver break, a short circuit in the connection wiring, a wrong connection or no excitation signal. Remove and re-apply the power to reset
RedHeatsink over-temperatureExcessive heatsink temperature (limit 95 °C at the heatsink). No reset action is required, the fault clears when the heatsink has cooled
RedMotor over-temperatureExcessive motor temperature. No reset action is required, the fault clears when the motor has cooled
RedHigh IrmsI²t current limiting rather than a trip: the drive is delivering the nominal current set by the SW2 switches and the green LED stays lit. Caused by a high duty cycle with frequent acceleration, frequent direction reversal, or an undersized drive
YellowClamp activeLit while the braking resistor is in use
Remote monitoring outputs
ContactsDrive normalPins 9 and 10 of the signal connector are internally connected while the green LED is lit, and open when a fault is detected, so they can operate a remote control power switch
Open collectorI²t limitingNormally conducting (logic 0) and open circuit while the drive is in I²t limiting

If the green LED stays out, check the supply voltage is in range, look for a short circuit between connector pins, check the wiring of the output connector and check the braking resistor has not overheated. If the LED only goes out when the drive is enabled, check that no motor cable wire is grounded.

24/7 emergency call-outs

MaxAx fault on your machine?

Send us the fault indication for a free fault assessment, or call 0161 399 0042 for 24/7 emergency call-outs. Fixed-price quote within 24 hours of your unit arriving, with a 12-month warranty.